HVREX_a019 — Shunt Tcr Cal Not Used

Full alert identifier: HVREX_a019_ShuntTcrCalNotUsed

Alert description

The shunt thermal coefficient of resistance (TCR) calibrations are not being used for high voltage (HV) current sensing. The default shunt TCR coefficients will be used and current measurement accuracy may be reduced.

Potential impact

The default shunt TCR coefficients will be used for high voltage (HV) current sensing. Shunt current measurement accuracy may be reduced.

Set condition

The stored shunt bar resistance is invalid or the written gain is outside the allowed tolerance.

Clear condition

The stored shunt bar resistance is valid and the written gain is within the allowed tolerance.

Signals to check

These diagnostic fields are associated with HVREX_a019. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Stored Coeff A Valid HVREX_a019_storedCoeffAValid —
Stored Coeff B Valid HVREX_a019_storedCoeffBValid —
Stored Coeff C Valid HVREX_a019_storedCoeffCValid —
Stored Coeff D Valid HVREX_a019_storedCoeffDValid —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of HVREX_a019.