HVREX_a018 — Shunt Bar Cal Not Used

Full alert identifier: HVREX_a018_ShuntBarCalNotUsed

Alert description

The programmed shunt bar resistance calibration is not being used for high voltage (HV) current sensing. The default shunt bar resistance will be used and current measurement accuracy may be reduced.

Potential impact

The default shunt bar resistance will be used for high voltage (HV) current sensing. Shunt current measurement accuracy may be reduced.

Set condition

The stored shunt bar resistance is invalid or the written gain is outside the allowed tolerance.

Clear condition

The stored shunt bar resistance is valid and the written gain is within the allowed tolerance.

Signals to check

These diagnostic fields are associated with HVREX_a018. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Stored Bar Resistance HVREX_a018_storedBarResistance
32767
SNA
nOhms
Stored Bar Resistance Valid HVREX_a018_storedBarResistanceValid —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of HVREX_a018.