HVREX_a017 — Shunt Asic Cal Not Used

Full alert identifier: HVREX_a017_ShuntAsicCalNotUsed

Alert description

The programmed shunt application-specific integrated circuit (ASIC) calibration is not being used for high voltage (HV) current sensing. The default shunt ASIC gain will be used and current measurement accuracy may be reduced.

Potential impact

The default shunt ASIC gain will be used for high voltage (HV) current sensing. Shunt current measurement accuracy may be reduced.

Set condition

The stored shunt ASIC gain is invalid or the written gain is outside the allowed tolerance.

Clear condition

The stored shunt ASIC gain is valid and the written gain is within the allowed tolerance.

Signals to check

These diagnostic fields are associated with HVREX_a017. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Asic Channel HVREX_a017_asicChannel —
Stored Asic Gain Pct HVREX_a017_storedAsicGainPct
-8388608
SNA
percent
Stored Asic Gain Valid HVREX_a017_storedAsicGainValid —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of HVREX_a017.

Browse all HVREX alert codes