HVBATT_a746 — Bp2 Soc Imbalance
Full alert identifier: HVBATT_a746_Bp2SocImbalance
Alert description
The battery management system (BMS) detects a possible state of charge (SOC) imbalance.
Potential impact
Maximum SOC is reduced to 50%.
Set condition
The BMS detects that the difference between the most-charged brick and the least-charge brick in the high voltage (HV) pack is greater than the acceptable threshold.
Clear condition
The BMS has detected that the difference between the maximum brick voltage and the minimum brick voltage is below the acceptable threshold.
Signals to check
These diagnostic fields are associated with HVBATT_a746. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Avg Brick Soc
HVBATT_
|
% |
Max Brick Soc
HVBATT_
|
% |
Max Brick Soc Id
HVBATT_
|
— |
Min Brick Soc
HVBATT_
|
% |
Min Brick Soc Id
HVBATT_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of HVBATT_a746.