HVBATT_a737 — Bp2 Cac Imbalance Limp
Full alert identifier: HVBATT_a737_Bp2CacImbalanceLimp
Alert description
Calculated Amp-hour Capacity (CAC) difference of bricks within a module exceeds acceptable threshold. This results in reduced battery performance and limits maximum range. Vehicle enters Battery Management System (BMS) limp mode.
Potential impact
BMS limp mode is triggered, with another alert present to indicate this condition.
Set condition
The estimated imbalance between the average CAC and minimum CAC within a single module exceeds the alert set threshold (CAC imbalance is not within acceptable range)
Clear condition
The estimated CAC imbalance is under the alert clear threshold (CAC imbalance is within acceptable range)
Signals to check
These diagnostic fields are associated with HVBATT_a737. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Avg Brick Cac
HVBATT_
|
Ah |
Min Brick Cac
HVBATT_
|
Ah |
Min Brick Cac Id
HVBATT_
|
— |
Mod Cac Imbalance Pct
HVBATT_
|
% |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of HVBATT_a737.