Skip to content

HVBATT_a745 — Bp1 Soc Imbalance

Full alert identifier: HVBATT_a745_Bp1SocImbalance

Alert description

The battery management system (BMS) detects a possible state of charge (SOC) imbalance.

Potential impact

Maximum SOC is reduced to 50%.

Set condition

The BMS detects that the difference between the most-charged brick and the least-charge brick in the high voltage (HV) pack is greater than the acceptable threshold.

Clear condition

The BMS has detected that the difference between the maximum brick voltage and the minimum brick voltage is below the acceptable threshold.

Signals to check

These diagnostic fields are associated with HVBATT_a745. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Avg Brick Soc HVBATT_a745_avgBrickSoc %
Max Brick Soc HVBATT_a745_maxBrickSoc %
Max Brick Soc Id HVBATT_a745_maxBrickSocId
255
SNA
—
Min Brick Soc HVBATT_a745_minBrickSoc %
Min Brick Soc Id HVBATT_a745_minBrickSocId
255
SNA
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of HVBATT_a745.

Browse all HVBATT alert codes