Skip to content

HVBATT_a115 — Hs Pyro Squib Resistance Low

Full alert identifier: HVBATT_a115_HsPyroSquibResistanceLow

Alert description

The high side pyro squib resistance is too high.

Potential impact

High-side pack HV will be blocked, charge and drive may be unavailable.

Set condition

The measured resistance between high side pyro-P and pyro-N is lower than the minimum limit.

Clear condition

The measured resistance between high side pyro-P and pyro-N is higher than the minimum limit.

Signals to check

These diagnostic fields are associated with HVBATT_a115. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Hs Pyro Squib Resistance HVBATT_a115_hsPyroSquibResistance Ohm

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of HVBATT_a115.

Browse all HVBATT alert codes