HVBATT_a115 — Hs Pyro Squib Resistance Low
Full alert identifier: HVBATT_a115_HsPyroSquibResistanceLow
Alert description
The high side pyro squib resistance is too high.
Potential impact
High-side pack HV will be blocked, charge and drive may be unavailable.
Set condition
The measured resistance between high side pyro-P and pyro-N is lower than the minimum limit.
Clear condition
The measured resistance between high side pyro-P and pyro-N is higher than the minimum limit.
Signals to check
These diagnostic fields are associated with HVBATT_a115. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Hs Pyro Squib Resistance
HVBATT_
|
Ohm |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of HVBATT_a115.