HVBATT_a098 — Ls Pyro Squib Resistance Low
Full alert identifier: HVBATT_a098_LsPyroSquibResistanceLow
Alert description
The low side pyro squib resistance is too low.
Potential impact
Low-side pack HV will be blocked, charge and drive may be unavailable.
Set condition
The measured resistance between low side pyro-P and pyro-N is lower than the minimum limit.
Clear condition
The measured resistance between low side pyro-P and pyro-N is higher than the minimum limit.
Signals to check
These diagnostic fields are associated with HVBATT_a098. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Ls Pyro Squib Resistance
HVBATT_
|
Ohm |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of HVBATT_a098.