Skip to content

HVBATT_a097 — Ls Pyro Squib Resistance High

Full alert identifier: HVBATT_a097_LsPyroSquibResistanceHigh

Alert description

The low side pyro squib resistance is too high.

Potential impact

Low-side pack HV will be blocked, charge and drive may be unavailable.

Set condition

The measured resistance between low side pyro-P and pyro-N is higher than the maximum limit.

Clear condition

The measured resistance between low side pyro-P and pyro-N is lower than the maximum limit.

Signals to check

These diagnostic fields are associated with HVBATT_a097. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Ls Pyro Squib Resistance HVBATT_a097_lsPyroSquibResistance Ohm

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of HVBATT_a097.

Browse all HVBATT alert codes