HVBATT_a097 — Ls Pyro Squib Resistance High
Full alert identifier: HVBATT_a097_LsPyroSquibResistanceHigh
Alert description
The low side pyro squib resistance is too high.
Potential impact
Low-side pack HV will be blocked, charge and drive may be unavailable.
Set condition
The measured resistance between low side pyro-P and pyro-N is higher than the maximum limit.
Clear condition
The measured resistance between low side pyro-P and pyro-N is lower than the maximum limit.
Signals to check
These diagnostic fields are associated with HVBATT_a097. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Ls Pyro Squib Resistance
HVBATT_
|
Ohm |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of HVBATT_a097.