HVBATT_a112 — Hs Pyro Sr Fet Bad

Full alert identifier: HVBATT_a112_HsPyroSrFetBad

Alert description

The high side pyro SF FET is non-functional.

Potential impact

The high side pack will not be able to come online.

Set condition

The high side pyro-N voltage does not fall to within a margin of zero volts when the SR FET is enabled.

Clear condition

The high side pyro-N voltage falls to within a margin of zero volts when the SR FET is enabled.

Signals to check

These diagnostic fields are associated with HVBATT_a112. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Hs Pyro Sr Fet Voltage HVBATT_a112_hsPyroSrFetVoltage V

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of HVBATT_a112.

Browse all HVBATT alert codes