HVBATT_a095 — Ls Pyro Sr Fet Bad

Full alert identifier: HVBATT_a095_LsPyroSrFetBad

Alert description

The low side pyro SR FET is non-functional.

Potential impact

Low-side pack HV will be blocked, charge and drive may be unavailable.

Set condition

The low side pyro-N voltage does not fall to within a margin of zero volts when the SR FET is enabled.

Clear condition

The low side pyro-N voltage falls to within a margin of zero volts when the SR FET is enabled.

Signals to check

These diagnostic fields are associated with HVBATT_a095. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Ls Pyro Sr Fet Voltage HVBATT_a095_lsPyroSrFetVoltage V

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of HVBATT_a095.