HVBATT_a107 — Hs Pyro P Leak Bad After Sr Fet Test
Full alert identifier: HVBATT_a107_HsPyroPLeakBadAfterSrFetTest
Alert description
The high side pyro-P leakage current is bad shortly following the SR FET test.
Potential impact
High-side pack HV will be blocked, charge and drive may be unavailable.
Set condition
The high side pyro-P leakage current exceeds tolerance shortly following the SR FET test.
Clear condition
The high side pyro-P leakage current is within tolerance after the SR FET test is performed.
Signals to check
These diagnostic fields are associated with HVBATT_a107. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Hs Pyro P Leak Voltage
HVBATT_
|
V |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of HVBATT_a107.