EGGLEFTVC_a255 — Seat Lift HC Enc Stl Dbg
Full alert identifier: EGGLEFTVC_a255_seatLiftHCEncStlDbg
Alert description
The seat lift motor encoder has unexpectedly stalled.
Potential impact
The seat lift motor encoder may increment incorrectly if an obstruction is encountered.
Set condition
Current draw exceeds 70% of the stall limit, and the encoder does not move for 100ms.
Clear condition
The motor is not in a movement state. It may also be in a movement state, but has not detected a high current motor stall.
Signals to check
These diagnostic fields are associated with EGGLEFTVC_a255. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Seat Motor Current
EGGLEFTVC_
|
A |
Seat Motor D Current
EGGLEFTVC_
|
A |
Seat Motor Pos Real
EGGLEFTVC_
|
mm |
Seat Motor State
EGGLEFTVC_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EGGLEFTVC_a255.