Alert description

The seat tilt motor encoder has unexpectedly stalled.

Potential impact

The seat tilt motor encoder may increment incorrectly if an obstruction is encountered.

Set condition

Current draw exceeds 70% of the stall limit, and the encoder does not move for 100ms.

Clear condition

The motor is not in a movement state. It may also be in a movement state, but has not detected a high current motor stall.

Signals to check

These diagnostic fields are associated with EGGLEFTVC_a253. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Seat Motor Current EGGLEFTVC_a253_seatMotorCurrent A
Seat Motor D Current EGGLEFTVC_a253_seatMotorDCurrent A
Seat Motor Pos Real EGGLEFTVC_a253_seatMotorPosReal mm
Seat Motor State EGGLEFTVC_a253_seatMotorState
0
STOPPED
1
MOVING UP
2
MOVING DOWN
3
RECALLING
4
CALIBRATING
5
UNDEFINED
—