DIR_a107 — Fpga Error
Full alert identifier: DIR_a107_fpgaError
Alert description
The Drive Inverter (DIx) has detected an error communicating with the Field Programmable Gate Array (FPGA).
Potential impact
The DIx Gate Drive Unit may not be able to receive data from the Pedal Monitor. The vehicle's drive cycle may not function as expected.
Set condition
DIx has detected an error communicating with FPGA. There may be a condition affecting the DIx control board functionality.
Clear condition
The DIx no longer detects an error communicating with FPGA. May require DIx be replaced.
Signals to check
These diagnostic fields are associated with DIR_a107. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Fpga Boot Version
DIR_
|
— |
Fpga Fault Active
DIR_
|
— |
Fpga Master Active
DIR_
|
— |
Fpga Version
DIR_
|
— |
Fpga Warning Active
DIR_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of DIR_a107.