Skip to content

DIR_a096 — Memory Error

Full alert identifier: DIR_a096_memoryError

Alert description

The drive interface (DI) or drive inverter (DIx) electronic control unit (ECU) detects a memory check error.

Potential impact

The DI processor may reset, and other functionality may be impacted due to memory corruption.

Set condition

The bootloader cyclic redundancy check (CRC) or application CRC is not expected, or the RAM constants do not match with initialization segment in flash.

Clear condition

Clears automatically 5 seconds after being set.

Signals to check

These diagnostic fields are associated with DIR_a096. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Boot Flash DIR_a096_boot_flash —
Const Fast DIR_a096_const_fast —
Mem Data DIR_a096_mem_data —
Mem Regs DIR_a096_mem_regs —
Text Fast DIR_a096_text_fast —
Text Flash DIR_a096_text_flash —
Word 1 DIR_a096_word1 —
Word 2 DIR_a096_word2 —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of DIR_a096.

Browse all DIR alert codes