Skip to content

DIR_a097 — Eeprom Error

Full alert identifier: DIR_a097_eepromError

Alert description

The drive interface (DI) or drive inverter (DIx) electronic control unit (ECU) detects an electrically erasable programmable read-only memory (EEPROM) read/write access error. Check for other alerts that may be set as a result.

Potential impact

The DI is not able to store any record in EEPROM where the error is located, which impacts functionality on the next boot up.

Set condition

There are read/write issues to EEPROM.

Clear condition

Clears when the vehicle is in Drive or Reverse if triggered on a primary unit, or when the unit is enabled if triggered on a secondary unit.

Signals to check

These diagnostic fields are associated with DIR_a097. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Argument DIR_a097_argument —
Error Type DIR_a097_errorType
0
OPEN
1
READ
2
WRITE
3
CRC
4
LOST
5
DPOT READ
6
DPOT WRITE
—
Line Number DIR_a097_lineNumber —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of DIR_a097.

Browse all DIR alert codes