Alert description

Alert for software trigger of mechanical safe state two-phase disconnect device.

Potential impact

The motor is permanently disabled.

Set condition

Software detects a shorted semiconductor switch. The alert log signals provide detailed trigger algorithm info.

Clear condition

Clears when low voltage (LV) power is removed from drive unit or a non-drive/drive cycle occurs

Signals to check

These diagnostic fields are associated with DIREL_a244. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Desat High Side DIREL_a244_desatHighSide —
Desat Low Side DIREL_a244_desatLowSide —
Flyback Fault DIREL_a244_flybackFault —
Gate Drive IC Undervoltage DIREL_a244_gateDriveICUndervoltage —
Ir Sensor V DIREL_a244_irSensorV V
Plausible Single Switch Short Only DIREL_a244_plausibleSingleSwitchShortOnly —
Post Short Test Failed DIREL_a244_postShortTestFailed —
Single Switch Short DIREL_a244_singleSwitchShort —
Show 1 more field
Signal Unit
Uds Self Test DIREL_a244_udsSelfTest —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of DIREL_a244.