Skip to content

DIREL_a016 — Safe State Applied

Full alert identifier: DIREL_a016_safeStateApplied

Alert description

The Drive Inverter (DIx) power stage has applied a safe state.

Potential impact

Some DIx features may be disabled, or may not function expected. The Drive Unit may not function as expected.

Set condition

The DIx power stage has applied a safe state.

Clear condition

The DIx no longer applies a safe state.

Signals to check

These diagnostic fields are associated with DIREL_a016. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Asc Monitor DIREL_a016_ascMonitor —
Gate Drive Fault Line DIREL_a016_gateDriveFaultLine —
Motor RPM DIREL_a016_motorRPM RPM
New Safe State DIREL_a016_newSafeState
0
NONE
1
ALL OFF
2
3PS HIGH
3
3PS LOW
—
Old Safe State DIREL_a016_oldSafeState
0
NONE
1
ALL OFF
2
3PS HIGH
3
3PS LOW
—
Pedal Monitor Pre Watchdog DIREL_a016_pedalMonitorPreWatchdog —
Safety I Cfault Line DIREL_a016_safetyICfaultLine —
Torque Motor DIREL_a016_torqueMotor Nm
Show 2 more fields
Signal Unit
Trigger Event DIREL_a016_triggerEvent —
Uncontrolled Regen Zone DIREL_a016_uncontrolledRegenZone —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of DIREL_a016.

Browse all DIREL alert codes