Skip to content

DIREL_a011 — Sw Power Stage Not Ready

Full alert identifier: DIREL_a011_swPowerStageNotReady

Alert description

The Drive Inverter (DIx) power stage is not ready. There may be a condition affecting the DIx control board.

Potential impact

DIx may not function as expected.

Set condition

The DIx power stage is not ready. One of the pre-drive gate driver checks has failed. There may be a condition affecting the DIx control board.

Clear condition

The DIx power stage is ready and functions as expected.

Signals to check

These diagnostic fields are associated with DIREL_a011. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Bad Data Expected DIREL_a011_badDataExpected —
Bad Data Read DIREL_a011_badDataRead —
Bad Gate Drive IC DIREL_a011_badGateDriveIC —
Code Branch DIREL_a011_codeBranch —
Phase A High DIREL_a011_phaseAHigh —
Phase A Low DIREL_a011_phaseALow —
Phase B High DIREL_a011_phaseBHigh —
Phase B Low DIREL_a011_phaseBLow —
Show 4 more fields
Signal Unit
Phase C High DIREL_a011_phaseCHigh —
Phase C Low DIREL_a011_phaseCLow —
Reason DIREL_a011_reason
0
GATE DRIVE SUPPLY
1
REG DATA MISMATCH
2
CRC MISMATCH
3
FAULT DURING CONFIG
4
SPI ERROR
—
Reg Address DIREL_a011_regAddress —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of DIREL_a011.

Browse all DIREL alert codes