CP_a154 — Ac Charging Stopped OT
Full alert identifier: CP_a154_acChargingStoppedOT
Alert description
The charge port inlet pin temperature has reached an unacceptable level (greatly exceeds normal operating range), causing AC charging to stop.
Potential impact
AC charging will be interrupted and remain unavailable until a charge cable cycle occurs (disconnect and reconnect) and the charge port inlet pin temperature returns to normal operating range.
Set condition
The charge port inlet pin temperature reaches a level where it is unacceptable to continue AC charging (temperature detected greatly exceeds normal operating range).
Clear condition
The charge cable is disconnected from the charge port inlet. Note: Alert will continue to set until the charge port inlet pin temperature is detected within normal operating range.
Signals to check
These diagnostic fields are associated with CP_a154. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Ac Pin Temp 1
CP_
|
C |
Ac Pin Temp 2
CP_
|
C |
Ac Pin Temp Velocity
CP_
|
C/min |
Ambient Temp
CP_
|
C |
Pcs Line Charge Current
CP_
|
A |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CP_a154.