Skip to content

CP_a113 — Inlet Heater Short Circuit

Full alert identifier: CP_a113_inletHeaterShortCircuit

Alert description

The charge port (CP) detects a short circuit on the inlet heater hardware.

Potential impact

The CP inlet heater does not work and the CP may remain frozen, requiring defrosting by other means.

Set condition

The CP ECU detects that the current going through the inlet heater is higher than 4.5A.

Clear condition

The UI defrost command is set to low.

Signals to check

These diagnostic fields are associated with CP_a113. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Heater Current CP_a113_heaterCurrent A
Heater Temperature CP_a113_heaterTemperature
255
SNA
C

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CP_a113.

Browse all CP alert codes