CP_a113 — Inlet Heater Short Circuit
Full alert identifier: CP_a113_inletHeaterShortCircuit
Alert description
The charge port (CP) detects a short circuit on the inlet heater hardware.
Potential impact
The CP inlet heater does not work and the CP may remain frozen, requiring defrosting by other means.
Set condition
The CP ECU detects that the current going through the inlet heater is higher than 4.5A.
Clear condition
The UI defrost command is set to low.
Signals to check
These diagnostic fields are associated with CP_a113. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Heater Current
CP_
|
A |
Heater Temperature
CP_
|
C |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CP_a113.