CP_a111 — Inlet Heater Unable To Heat

Full alert identifier: CP_a111_inletHeaterUnableToHeat

Alert description

The charge port (CP) electronic control unit (ECU) detects that the CP inlet heater is not able to heat properly.

Potential impact

The CP inlet heater does not work and the CP may remain frozen, requiring defrosting by other means.

Set condition

The CP ECU detects that the inlet heater was unable to reach the inlet defrosting temperature.

Clear condition

The UI defrost command is set to low.

Signals to check

These diagnostic fields are associated with CP_a111. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
VC Temp Ambient Filtered CP_a111_VC_tempAmbientFiltered
0
SNA
degC
Heater Temperature CP_a111_heaterTemperature
255
SNA
C

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CP_a111.