Skip to content

CMPT_a028 — Gate Driver Not Ready

Full alert identifier: CMPT_a028_gateDriverNotReady

Alert description

The compressor high voltage powerstage gate drivers reported improper input voltage preventing their operation.

Potential impact

The compressor will not operate.

Set condition

Any gate driver is reporting an electrical condition affecting its functionality.

Clear condition

All gate driver electrical issues have cleared.

Signals to check

These diagnostic fields are associated with CMPT_a028. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
12 V Voltage CMPT_a028_12vVoltage V
Fet Temp AL CMPT_a028_fetTemp_AL
255
SNA
degC
Gdps Est Temp CMPT_a028_gdpsEstTemp
255
SNA
degC
Lv State CMPT_a028_lvState
0
OFF
1
ON
2
GOING DOWN
3
FAULT
—
Pcba Temp CMPT_a028_pcbaTemp
255
SNA
degC
Pgood AH CMPT_a028_pgoodAH —
Pgood BH CMPT_a028_pgoodBH —
Pgood CH CMPT_a028_pgoodCH —
Show 7 more fields
Signal Unit
Pgood LO CMPT_a028_pgoodLO —
Rdy AH CMPT_a028_rdyAH —
Rdy AL CMPT_a028_rdyAL —
Rdy BH CMPT_a028_rdyBH —
Rdy BL CMPT_a028_rdyBL —
Rdy CH CMPT_a028_rdyCH —
Rdy CL CMPT_a028_rdyCL —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CMPT_a028.

Browse all CMPT alert codes