CMPT_a012 — Gate Driver Fault

Full alert identifier: CMPT_a012_gateDriverFault

Alert description

The compressor high voltage powerstage gate drivers reported an electrical condition preventing their operation.

Potential impact

The compressor will not operate.

Set condition

Any gate driver is reporting an electrical condition affecting its functionality.

Clear condition

All gate driver electrical issues have cleared.

Signals to check

These diagnostic fields are associated with CMPT_a012. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Flt AH CMPT_a012_fltAH —
Flt AL CMPT_a012_fltAL —
Flt BH CMPT_a012_fltBH —
Flt BL CMPT_a012_fltBL —
Flt CH CMPT_a012_fltCH —
Flt CL CMPT_a012_fltCL —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CMPT_a012.