Skip to content

CMPT_a024 — Gate Drive Power Supply Retries Expired

Full alert identifier: CMPT_a024_gateDrivePowerSupplyRetriesExpired

Alert description

One of the gate driver power supplies expired its available retries.

Potential impact

The HV compressor will stop operating as power to the corresponding gate driver becomes insufficient.

Set condition

The internal gate drive power supply had to shut down too many consecutive times. The compressor is aborting retries to prevent possible additional hardware damage.

Clear condition

This alert clears on the next power cycle.

Signals to check

These diagnostic fields are associated with CMPT_a024. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Channel CMPT_a024_channel —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CMPT_a024.

Browse all CMPT alert codes