CC_a006 — Input Over Current
Full alert identifier: CC_a006_inputOverCurrent
Alert description
Contactors opened due to measured current exceeding configured unit current limit or sharing network allocated current.
Potential impact
Wall connector will stop charging and retry at most 3 times before waiting for the cable to be cycled.
Set condition
Measured current exceeds configured limit or sharing network allocation by 10 percent + 1 A root mean square (RMS).
Clear condition
Contactors open for 10 seconds and less than 4 automatic retry attempts, or charge cable cycled.
Signals to check
These diagnostic fields are associated with CC_a006. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Line 1 Current
CC_
|
A |
Line 2 Current
CC_
|
A |
Line 3 Current
CC_
|
A |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CC_a006.