Skip to content

CC_a006 — Input Over Current

Full alert identifier: CC_a006_inputOverCurrent

Alert description

Contactors opened due to measured current exceeding configured unit current limit or sharing network allocated current.

Potential impact

Wall connector will stop charging and retry at most 3 times before waiting for the cable to be cycled.

Set condition

Measured current exceeds configured limit or sharing network allocation by 10 percent + 1 A root mean square (RMS).

Clear condition

Contactors open for 10 seconds and less than 4 automatic retry attempts, or charge cable cycled.

Signals to check

These diagnostic fields are associated with CC_a006. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Line 1 Current CC_a006_line1Current A
Line 2 Current CC_a006_line2Current A
Line 3 Current CC_a006_line3Current A

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CC_a006.

Browse all CC alert codes