Skip to content

CC_a041 — Input Wiring Foldback

Full alert identifier: CC_a041_inputWiringFoldback

Alert description

Input wiring terminals are too hot as detected by non-contact infrared (IR) sensor.

Potential impact

Charging rate will be reduced by 50 percent and red LEDs blink once.

Set condition

Input wiring terminal IR emission exceeds threshold.

Clear condition

Input wiring terminal IR emission falls below threshold.

Signals to check

These diagnostic fields are associated with CC_a041. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Input Thermopile CC_a041_inputThermopile V
Input Thermopile Dvdt CC_a041_inputThermopileDvdt V/sec

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CC_a041.

Browse all CC alert codes