CC_a003 — CCID Tripped
Full alert identifier: CC_a003_CCIDTripped
Alert description
Ground fault current exceeded threshold.
Potential impact
Wall connector will not allow charging until ground fault current path is corrected and the test rerun.
Set condition
Ground fault current exceeded threshold.
Clear condition
Ground fault current has been corrected, and the test rerun. Test reruns after 15 minutes (non-EU), cable cycle, or reset button.
Signals to check
These diagnostic fields are associated with CC_a003. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Dc Gfci Current
CC_
|
A |
Gfci Fault Bucket
CC_
|
— |
Gfci Fault Reason
CC_
|
— |
Gfci Rms Current
CC_
|
A |
Gfci Rms Current Avg
CC_
|
A |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CC_a003.