CC_a003 — CCID Tripped

Full alert identifier: CC_a003_CCIDTripped

Alert description

Ground fault current exceeded threshold.

Potential impact

Wall connector will not allow charging until ground fault current path is corrected and the test rerun.

Set condition

Ground fault current exceeded threshold.

Clear condition

Ground fault current has been corrected, and the test rerun. Test reruns after 15 minutes (non-EU), cable cycle, or reset button.

Signals to check

These diagnostic fields are associated with CC_a003. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Dc Gfci Current CC_a003_dcGfciCurrent A
Gfci Fault Bucket CC_a003_gfciFaultBucket —
Gfci Fault Reason CC_a003_gfciFaultReason
0
SNA
1
AC LPF
2
AC PEAK
3
DC LPF
4
DC PEAK
—
Gfci Rms Current CC_a003_gfciRmsCurrent A
Gfci Rms Current Avg CC_a003_gfciRmsCurrentAvg A

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CC_a003.

Browse all CC alert codes