CC_a004 — CCID Self Test Fault
Full alert identifier: CC_a004_CCIDSelfTestFault
Alert description
Ground fault detection circuit self-test failed.
Potential impact
Wall connector will not allow charging until the ground fault circuit self-test passes.
Set condition
Ground fault detection circuit self-test failed.
Clear condition
Ground fault detection circuit self-test passed after being rerun. Test reruns after 15 minutes (non-EU), cable cycle, or reset button.
Signals to check
These diagnostic fields are associated with CC_a004. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Gfci Asic Error Bitfield
CC_
|
— |
Gfci Error Reason
CC_
|
— |
Gfci Self Test Current
CC_
|
A |
Gfci Self Test Duty
CC_
|
A |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CC_a004.