Skip to content

CC_a004 — CCID Self Test Fault

Full alert identifier: CC_a004_CCIDSelfTestFault

Alert description

Ground fault detection circuit self-test failed.

Potential impact

Wall connector will not allow charging until the ground fault circuit self-test passes.

Set condition

Ground fault detection circuit self-test failed.

Clear condition

Ground fault detection circuit self-test passed after being rerun. Test reruns after 15 minutes (non-EU), cable cycle, or reset button.

Signals to check

These diagnostic fields are associated with CC_a004. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Gfci Asic Error Bitfield CC_a004_gfciAsicErrorBitfield —
Gfci Error Reason CC_a004_gfciErrorReason
0
SNA
1
IO ERROR
2
ASIC REASON
3
DC OFFSET ERROR
4
AC OFFSET ERROR
5
TEST SIGNAL ERROR
—
Gfci Self Test Current CC_a004_gfciSelfTestCurrent A
Gfci Self Test Duty CC_a004_gfciSelfTestDuty A

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CC_a004.

Browse all CC alert codes