Skip to content

CC_a014 — Mcu Self Test Fault

Full alert identifier: CC_a014_mcuSelfTestFault

Alert description

Wall connector microcontroller internal self-test fault.

Potential impact

Wall connector will not operate until self-test passes.

Set condition

Wall connector microcontroller failed internal self-test.

Clear condition

Wall connector microcontroller passes internal self-test.

Signals to check

These diagnostic fields are associated with CC_a014. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Failure Cause CC_a014_failureCause
1
OTHER
2
CONFIG NOT RECEIVED
3
METER INIT FAILED
4
DCGFCI INIT FAILED
—
Meter Fault Address CC_a014_meterFaultAddress —
Meter Fault Data CC_a014_meterFaultData —
Meter Retry Count CC_a014_meterRetryCount —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CC_a014.

Browse all CC alert codes