Falcon Wing door controller alerts
Browse 161 BCFALCP alert codes and open an entry for its description and recorded conditions.
BCFALCP alert codes
Showing 101–150 of 161
- BCFALCP_a152 — Lower Front No Resp BCFALCP_a152_lowerFrontNoResp
- BCFALCP_a153 — Lower Rear No Resp BCFALCP_a153_lowerRearNoResp
- BCFALCP_a159 — IMU Sensitive Trigger BCFALCP_a159_IMUSensitiveTrigger
- BCFALCP_a160 — IMU Obstacle Detected BCFALCP_a160_IMUObstacleDetected The Falcon Door Body Controller Inertial Measurement Unit (IMU) has detected an obstacle and stopped door motion.
- BCFALCP_a161 — Door USS Obs Detected BCFALCP_a161_DoorUSSObsDetected
- BCFALCP_a162 — Roof USS Obs Detected BCFALCP_a162_RoofUSSObsDetected
- BCFALCP_a163 — Capacit Obs Detected BCFALCP_a163_CapacitObsDetected
- BCFALCP_a164 — Inductiv Obs Detected BCFALCP_a164_InductivObsDetected
- BCFALCP_a165 — Pinch Obs Detected BCFALCP_a165_PinchObsDetected One of the two Falcon pinch strip sensor was pressed and stopped the door movement.
- BCFALCP_a166 — Cap Harness Err BCFALCP_a166_CapHarnessErr The EOL routine to learn the Genealogy may not have been run correctly
- BCFALCP_a167 — Cap Genealogy Err BCFALCP_a167_CapGenealogyErr The EOL routine to learn the Genealogy may not have been run correctly
- BCFALCP_a168 — Ind Harness Err BCFALCP_a168_IndHarnessErr The EOL routine to learn the Genealogy may not have been run correctly
- BCFALCP_a169 — Ind Genealogy Err BCFALCP_a169_IndGenealogyErr The EOL routine to learn the Genealogy may not have been run correctly
- BCFALCP_a170 — Upper Front Over Temp BCFALCP_a170_upperFrontOverTemp The Falcon Door Body Controller has estimated section actuator temperatures exceeding 100.0 deg C (212 deg F).
- BCFALCP_a171 — Upper Rear Over Temp BCFALCP_a171_upperRearOverTemp The Falcon Door Body Controller has estimated section actuator temperatures exceeding 100.0 deg C (212 deg F).
- BCFALCP_a172 — Lower Front Over Temp BCFALCP_a172_lowerFrontOverTemp The Falcon Door Body Controller has estimated section actuator temperatures exceeding 100.0 deg C (212 deg F).
- BCFALCP_a173 — Lower Rear Over Temp BCFALCP_a173_lowerRearOverTemp The Falcon Door Body Controller has estimated section actuator temperatures exceeding 100.0 deg C (212 deg F).
- BCFALCP_a174 — USS Roof Resonance Err BCFALCP_a174_USSRoofResonanceErr
- BCFALCP_a175 — USS Roof Reverb Err BCFALCP_a175_USSRoofReverbErr
- BCFALCP_a176 — USS Roof Not Captured BCFALCP_a176_USSRoofNotCaptured
- BCFALCP_a177 — USS Door Resonance Err BCFALCP_a177_USSDoorResonanceErr The Falcon Door Body Controller has detected the resonance period reported by the ultrasonic sensor is out of bounds.
- BCFALCP_a178 — USS Door Reverb Err BCFALCP_a178_USSDoorReverbErr
- BCFALCP_a179 — USS Door Not Captured BCFALCP_a179_USSDoorNotCaptured
- BCFALCP_a180 — Upper Current Thresh BCFALCP_a180_UpperCurrentThresh The Falcon Door Body Controller has detected the electrical current limit for the upper actuator has been exceeded.
- BCFALCP_a181 — Upper Traj Position BCFALCP_a181_UpperTrajPosition The Falcon Door Body Controller has detected the door section is deviating by 6 degrees away from its designated trajectory target path.
- BCFALCP_a182 — Upper Traj Speed BCFALCP_a182_UpperTrajSpeed The Falcon Door Body Controller has detected a deviation from the desired speed of the door section during opening at a rate of 9 degrees per second or upon closure at a speed of 7 degrees per second.
- BCFALCP_a183 — Upper Latch Entry BCFALCP_a183_UpperLatchEntry
- BCFALCP_a184 — Lower Current Thresh BCFALCP_a184_LowerCurrentThresh The Falcon Door Body Controller has detected the electrical current limit for the lower actuator's electrical current has been exceeded.
- BCFALCP_a185 — Lower Traj Position BCFALCP_a185_LowerTrajPosition The Falcon Door Body Controller has detected the door section is deviating by 6 degrees away from its designated trajectory target path.
- BCFALCP_a186 — Lower Traj Speed BCFALCP_a186_LowerTrajSpeed The Falcon Door Body Controller has detected a deviation from the desired speed of the door section during opening at a rate of 9 degrees per second or upon closure at a speed of 7 degrees per second.
- BCFALCP_a187 — Lower Latch Entry BCFALCP_a187_LowerLatchEntry
- BCFALCP_a188 — Door Mvmt USS No Change BCFALCP_a188_doorMvmtUSSNoChange The rear door's ultrasonic sensor has detected an object that is likely to be a false positive, and that presumably does not exist.
- BCFALCP_a190 — Roof USS Unstable BCFALCP_a190_RoofUSSUnstable This will be seen every time a obstacle enters or leaves the sensor field of view, so can be normal. Abnormal if alert persists when obstacles are not entering or exiting field of view.
- BCFALCP_a191 — Door USS Unstable BCFALCP_a191_DoorUSSUnstable This will be seen every time a obstacle enters or leaves the sensor field of view, so can be normal. Abnormal if alert persists when obstacles are not entering or exiting field of view.
- BCFALCP_a192 — eFuse Not Ready BCFALCP_a192_eFuseNotReady
- BCFALCP_a193 — Open To Fit Used BCFALCP_a193_openToFitUsed Falcon door is using the open to fit state due to a detected obstacle limiting the door opening space. See alert payload for more information on the limit source.
- BCFALCP_a194 — Open To Fit Mapping Was Used BCFALCP_a194_openToFitMappingWasUsed Dynamic mapping is being used for open to fit
- BCFALCP_a195 — Second Open Request Indoors BCFALCP_a195_secondOpenRequestIndoors A succesive door open request was used indoors
- BCFALCP_a196 — Open To Fit Due To Park Sensor BCFALCP_a196_openToFitDueToParkSensor Door is using the open to fit state due to the park sensors detecting obstacles that limits the door opening space.
- BCFALCP_a197 — Open To Fit Source Changed While Parked BCFALCP_a197_openToFitSourceChangedWhileParked The open to fit limit source changed to park sensors while the vehicle was not in motion
- BCFALCP_a200 — New Indoor Mode Clear Value DBG BCFALCP_a200_newIndoorModeClearValueDBG A new driving distance was calculated to clear indoor mode
- BCFALCP_a201 — Parked Indoor Mode DBG BCFALCP_a201_parkedIndoorModeDBG Falcon controller has just entered indoor mode
- BCFALCP_a258 — USS Roof Sns Blocked BCFALCP_a258_USS_RoofSnsBlocked Check SNS USS_alertMatrix for specific details of this alert
- BCFALCP_a259 — USS LH Sns Intrnl Fail BCFALCP_a259_USS_LHSnsIntrnlFail The ultrasonic sensor (USS) controller detects an internal condition affecting the driver-side USS.
- BCFALCP_a260 — USS LH Lin Comm Error BCFALCP_a260_USS_LHLinCommError The ultrasonic sensor (USS) controller detects a condition affecting the Local Interconnect Network (LIN) communication with the driver-side USS.
- BCFALCP_a261 — USS Roof Over Temp BCFALCP_a261_USS_RoofOverTemp CThe Falcon Door Roof Ultra-Sonic Sensor (USS) over temperature condition detected.
- BCFALCP_a262 — USS Roof Sns Int Fail BCFALCP_a262_USS_RoofSnsIntFail The ultrasonic sensor (USS) controller detects an internal condition affecting the roof USS.
- BCFALCP_a263 — USS Roof Lin Com Error BCFALCP_a263_USS_RoofLinComError The ultrasonic sensor (USS) controller detects a condition affecting the Local Interconnect Network (LIN) communication with the roof USS.
- BCFALCP_a264 — USS ECU Under Voltage BCFALCP_a264_USS_ECUUnderVoltage The ultrasonic sensor (USS) controller detects an undervoltage condition.
- BCFALCP_a265 — USS ECU Over Voltage BCFALCP_a265_USS_ECUOverVoltage The ultrasonic sensor (USS) controller detects an over voltage condition.