BCFALCP_a182 — Upper Traj Speed
Full alert identifier: BCFALCP_a182_UpperTrajSpeed
Alert description
The Falcon Door Body Controller has detected a deviation from the desired speed of the door section during opening at a rate of 9 degrees per second or upon closure at a speed of 7 degrees per second.
Potential impact
Multiple occurrences suggest possible hardware conditions in the door or interference from foreign objects and debris affecting door functionality.
Set condition
Deviation from the desired speed of the door section during opening at a rate of 9 degrees per second or upon closure of 7 degrees per second is detected.
Clear condition
A new door movement command is received.
Signals to check
Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.
| Signal | Unit |
|---|---|
Max Actuation Current
BCFALCP_
|
A |
Upper Door Angle
BCFALCP_
|
deg |
Upper Speed Diff
BCFALCP_
|
deg/s |
| Signal | Unit |
|---|---|
Door Mvmt Direction
BCFALCP_
|
— |
Upper Traj Speed
BCFALCP_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of BCFALCP_a182.