Skip to content

VCSEATD_a236 — Lumbar Over Pres A

Full alert identifier: VCSEATD_a236_lumbarOverPresA

Alert description

The bladder A has exceeded pressure limits

Potential impact

Damage to bladder or valve block

Set condition

Bladder pressure exceeds 1300hPa (absolute)

Clear condition

Bladder A does not exceed pressure limit

Signals to check

These diagnostic fields are associated with VCSEATD_a236. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Lumbar A Pressure Hpa VCSEATD_a236_lumbarAPressureHpa —
Lumbar A State VCSEATD_a236_lumbarAState
0
STOPPED
1
MOVING UP
2
MOVING DOWN
3
RECALLING
4
CALIBRATING
5
UNDEFINED
—
Lumbar B Pressure Hpa VCSEATD_a236_lumbarBPressureHpa —
Lumbar B State VCSEATD_a236_lumbarBState
0
STOPPED
1
MOVING UP
2
MOVING DOWN
3
RECALLING
4
CALIBRATING
5
UNDEFINED
—
Lumbar Diag Status VCSEATD_a236_lumbarDiagStatus —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCSEATD_a236.

Browse all VCSEATD alert codes