Skip to content

VCSEATD_a228 — Seat Enc Over Track

Full alert identifier: VCSEATD_a228_seatEncOverTrack

Alert description

The motor has traveled beyond the expected range

Potential impact

Seat may be in an unstable position or a mechanism may have failed

Set condition

seat position goes outside the acceptable range

Clear condition

The motor has returned to the expected range

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Seat Motor Current VCSEATD_a228_seatMotorCurrent A
Seat Motor Pos Real VCSEATD_a228_seatMotorPosReal mm
Signal Unit
Seat Motor Calibrated VCSEATD_a228_seatMotorCalibrated —
Seat Motor State VCSEATD_a228_seatMotorState
0
STOPPED
1
MOVING UP
2
MOVING DOWN
3
RECALLING
4
CALIBRATING
5
UNDEFINED
—
Seat Switch Back VCSEATD_a228_seatSwitchBack
0
SNA
1
OFF
2
ON
3
FAULT
—
Seat Switch Forward VCSEATD_a228_seatSwitchForward
0
SNA
1
OFF
2
ON
3
FAULT
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCSEATD_a228.

Browse all VCSEATD alert codes