VCRIGHT_a303 — eFuse Mgmt Window Lift
Full alert identifier: VCRIGHT_a303_eFuseMgmtWindowLift
Alert description
The window motors are disabled. The Right Vehicle Controller (VCRIGHT) Electronic Control Unit (ECU) detects an eFuse overcurrent event on the window bridge power feed.
Potential impact
Window control is disabled. Right window motor may not operate as expected.
Set condition
VCRIGHT detects an eFuse overcurrent event (or a trip) on the window bridges power feed. Voltage is above 8V for 200ms on at least one of the right window motor outputs while no outputs are being driven.
Clear condition
Alert clears automatically after 10 seconds. If alert asserts for a maximum of three times, loads will be disabled. VCRIGHT may require a reset.
Signals to check
These diagnostic fields are associated with VCRIGHT_a303. Check the alert's Payload in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
E Fuse Trip Count
VCRIGHT_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCRIGHT_a303.