VCRIGHT_a266 — Seat Lift Stall Debug
Full alert identifier: VCRIGHT_a266_seatLiftStallDebug
Alert description
The seat lift motor has unexpectedly stalled.
Potential impact
Motor will recalibrate if the stall is in an expected region, do nothing otherwise.
Set condition
Current draw exceeds stall limit.
Clear condition
The motor is not in a movement state. It may also be in a movement state, but has not detected a stall.
Signals to check
Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.
| Signal | Unit |
|---|---|
Seat Motor Current
VCRIGHT_
|
A |
Seat Motor D Current
VCRIGHT_
|
A |
Seat Motor Pos Real
VCRIGHT_
|
mm |
| Signal | Unit |
|---|---|
Seat Motor State
VCRIGHT_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCRIGHT_a266.