VCRIGHT_a263 — Seat Track Stall Debug

Full alert identifier: VCRIGHT_a263_seatTrackStallDebug

Alert description

The seat track motor has unexpectedly stalled.

Potential impact

Motor will recalibrate if the stall is in an expected region, do nothing otherwise.

Set condition

Current draw exceeds stall limit.

Clear condition

The motor is not in a movement state. It may also be in a movement state, but has not detected a stall.

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Seat Motor Current VCRIGHT_a263_seatMotorCurrent A
Seat Motor D Current VCRIGHT_a263_seatMotorDCurrent A
Seat Motor Pos Real VCRIGHT_a263_seatMotorPosReal mm
Signal Unit
Seat Motor State VCRIGHT_a263_seatMotorState
0
STOPPED
1
MOVING UP
2
MOVING DOWN
3
RECALLING
4
CALIBRATING
5
UNDEFINED
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCRIGHT_a263.

Browse all VCRIGHT alert codes