VCLEFT_a448 — Steering Col Up Down Endstop Cal
Full alert identifier: VCLEFT_a448_steeringColUpDownEndstopCal
Alert description
Steering column up / down motor end stop is not within the expected range.
Potential impact
Calibration may have been unsuccessful. Steering column profile recall may not operate as expected.
Set condition
The full range of up / down movement is less than 53mm or greater than 64mm.
Clear condition
New calibration attempt has started.
Signals to check
Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.
| Signal | Unit |
|---|---|
Endstop Position MM
VCLEFT_
|
mm |
| Signal | Unit |
|---|---|
Motor Type
VCLEFT_
|
— |
Check other alerts