VCLEFT_a386 — Steer Col Up Down Motor Under Current
Full alert identifier: VCLEFT_a386_steerColUpDownMotorUnderCurrent
Alert description
Steering column up/down motor current is too low while being driven
Potential impact
Steering column up/down motor may not be driven
Set condition
Steering column up/down motor is possibly disconnected or shorted
Clear condition
Steering column up/down motor is successfully driven, and enough current is seen
Signals to check
Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.
| Signal | Unit |
|---|---|
Current Position MM
VCLEFT_
|
mm |
Motor Current
VCLEFT_
|
A |
Saved Endstop Position MM
VCLEFT_
|
mm |
| Signal | Unit |
|---|---|
Motor Type
VCLEFT_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCLEFT_a386.