Skip to content

VCLEFT_a386 — Steer Col Up Down Motor Under Current

Full alert identifier: VCLEFT_a386_steerColUpDownMotorUnderCurrent

Alert description

Steering column up/down motor current is too low while being driven

Potential impact

Steering column up/down motor may not be driven

Set condition

Steering column up/down motor is possibly disconnected or shorted

Clear condition

Steering column up/down motor is successfully driven, and enough current is seen

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Current Position MM VCLEFT_a386_currentPositionMM mm
Motor Current VCLEFT_a386_motorCurrent A
Saved Endstop Position MM VCLEFT_a386_savedEndstopPositionMM mm
Signal Unit
Motor Type VCLEFT_a386_motorType —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCLEFT_a386.