VCLEFT_a266 — Seat Lift Stall Debug

Full alert identifier: VCLEFT_a266_seatLiftStallDebug

Alert description

The seat lift motor has unexpectedly stalled.

Potential impact

Motor will recalibrate if the stall is in an expected region, do nothing otherwise.

Set condition

Current draw exceeds stall limit.

Clear condition

The motor is not in a movement state. It may also be in a movement state, but has not detected a stall.

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Seat Motor Current VCLEFT_a266_seatMotorCurrent A
Seat Motor D Current VCLEFT_a266_seatMotorDCurrent A
Seat Motor Pos Real VCLEFT_a266_seatMotorPosReal mm
Signal Unit
Seat Motor State VCLEFT_a266_seatMotorState
0
STOPPED
1
MOVING UP
2
MOVING DOWN
3
RECALLING
4
CALIBRATING
5
UNDEFINED
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCLEFT_a266.

Browse all VCLEFT alert codes