Alert description

The seat track motor has unexpectedly stalled.

Potential impact

Motor will recalibrate if the stall is in an expected region, do nothing otherwise.

Set condition

Current draw exceeds stall limit.

Clear condition

The motor is not in a movement state. It may also be in a movement state, but has not detected a stall.

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Seat Motor Current VCLEFT_a263_seatMotorCurrent A
Seat Motor D Current VCLEFT_a263_seatMotorDCurrent A
Seat Motor Pos Real VCLEFT_a263_seatMotorPosReal mm
Signal Unit
Seat Motor State VCLEFT_a263_seatMotorState
0
STOPPED
1
MOVING UP
2
MOVING DOWN
3
RECALLING
4
CALIBRATING
5
UNDEFINED
—