Skip to content

VCFRONT_a280 — Refrig Liquid Pres Sns

Full alert identifier: VCFRONT_a280_refrigLiquidPresSns

Alert description

The vehicle controller detects the refrigerant liquid pressure sensor is experiencing an electrical condition (short or disconnect).

Potential impact

Cabin climate control system air conditioning and heating may be limited or unavailable. Powertrain performance may be limited.

Set condition

The refrigerant liquid pressure sensor reads a power rail or ground reference voltage.

Clear condition

The refrigerant liquid pressure sensor no longer reads a power rail or ground reference voltage.

Signals to check

These diagnostic fields are associated with VCFRONT_a280. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Sns Disconnect VCFRONT_a280_snsDisconnect —
Sns Rate Change Down VCFRONT_a280_snsRateChangeDown —
Sns Rate Change Up VCFRONT_a280_snsRateChangeUp —
Sns Short Circuit VCFRONT_a280_snsShortCircuit —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCFRONT_a280.

Browse all VCFRONT alert codes