VCFRONT_a280 — Refrig Liquid Pres Sns
Full alert identifier: VCFRONT_a280_refrigLiquidPresSns
Alert description
The vehicle controller detects the refrigerant liquid pressure sensor is experiencing an electrical condition (short or disconnect).
Potential impact
Cabin climate control system air conditioning and heating may be limited or unavailable. Powertrain performance may be limited.
Set condition
The refrigerant liquid pressure sensor reads a power rail or ground reference voltage.
Clear condition
The refrigerant liquid pressure sensor no longer reads a power rail or ground reference voltage.
Signals to check
These diagnostic fields are associated with VCFRONT_a280. Check the alert's Payload in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Sns Disconnect
VCFRONT_
|
— |
Sns Rate Change Down
VCFRONT_
|
— |
Sns Rate Change Up
VCFRONT_
|
— |
Sns Short Circuit
VCFRONT_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCFRONT_a280.