Skip to content

VCFRONT_a139 — Refrig Suct Pres Sns

Full alert identifier: VCFRONT_a139_refrigSuctPresSns

Alert description

The front vehicle controller (VCFRONT) detects the refrigerant suction pressure sensor is experiencing an electrical condition (short or disconnect).

Potential impact

Cabin climate control system air conditioning may be limited or unavailable. Powertrain performance may be limited.

Set condition

The refrigerant suction pressure sensor reads a power rail or ground reference voltage.

Clear condition

The refrigerant suction pressure sensor no longer reads a power rail or ground reference voltage.

Signals to check

These diagnostic fields are associated with VCFRONT_a139. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Sns Disconnect VCFRONT_a139_snsDisconnect —
Sns Rate Change Down VCFRONT_a139_snsRateChangeDown —
Sns Rate Change Up VCFRONT_a139_snsRateChangeUp —
Sns Short Circuit VCFRONT_a139_snsShortCircuit —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCFRONT_a139.

Browse all VCFRONT alert codes