VCBATT_a144 — Pump Rad IC Trans Fault
Full alert identifier: VCBATT_a144_pumpRadICTransFault
Alert description
The motor has a circuit warning. Powertrain performance may be limited.
Potential impact
The radiator pump will not run. Powertrain performance may be limited. The fault will clear when the condition is no longer present.
Set condition
The LV8907 integrated circuit has detected a warning that requires a stop
Clear condition
The LV8907 integrated circuit no longer detects a warning that requires a stop
Signals to check
These diagnostic fields are associated with VCBATT_a144. Check the alert's Payload in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Chp Under Voltage
VCBATT_
|
— |
Th Over Temperature
VCBATT_
|
— |
Vgl Under Voltage
VCBATT_
|
— |
Vs Over Voltage
VCBATT_
|
— |
Vs Under Voltage
VCBATT_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCBATT_a144.