Skip to content

VCBATT_a123 — Pump Rad IC Latch Fault

Full alert identifier: VCBATT_a123_pumpRadICLatchFault

Alert description

The motor has detected an electrical fault (short, disconnect, or internal). Powertrain performance may be limited.

Potential impact

The radiator pump will not run. Powertrain performance may be limited. The circuit will be reset to attempt to clear the fault.

Set condition

The LV8907 integrated circuit has detected a fault that requires a stop.

Clear condition

The LV8907 integrated circuit no longer detects a fault that requires a stop.

Signals to check

These diagnostic fields are associated with VCBATT_a123. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Fet Short Circuit VCBATT_a123_fetShortCircuit —
Locked Rotor VCBATT_a123_lockedRotor —
Over Current Error VCBATT_a123_overCurrentError —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCBATT_a123.

Browse all VCBATT alert codes