VCBATT_a126 — Thml Fan IC Warning

Full alert identifier: VCBATT_a126_thmlFanICWarning

Alert description

The motor has a circuit warning. HVAC cabin cooling (air conditioning) and powertrain performance may be limited.

Potential impact

The thermal fan may not run. HVAC cabin cooling (air conditioning) and powertrain performance may be limited.

Set condition

The LV8907 integrated circuit has detected a warning that should be reported.

Clear condition

The LV8907 integrated circuit no longer detects a warning that should be reported.

Signals to check

These diagnostic fields are associated with VCBATT_a126. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Junction Over Temp VCBATT_a126_junctionOverTemp —
Junction Temp Warning VCBATT_a126_junctionTempWarning —
Loss Of Speed Lock VCBATT_a126_lossOfSpeedLock —
Start Up Operation VCBATT_a126_startUpOperation —
Vcc Under Voltage VCBATT_a126_vccUnderVoltage —