VCBATT_a122 — Pump Bat IC Warning
Full alert identifier: VCBATT_a122_pumpBatICWarning
Alert description
The motor has a circuit warning. Powertrain performance may be limited.
Potential impact
The battery pump may not run. Powertrain performance may be limited.
Set condition
The LV8907 integrated circuit has detected a warning that should be reported.
Clear condition
The LV8907 integrated circuit no longer detects a fault that requires a stop.
Signals to check
These diagnostic fields are associated with VCBATT_a122. Check the alert's Payload in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Junction Over Temp
VCBATT_
|
— |
Junction Temp Warning
VCBATT_
|
— |
Loss Of Speed Lock
VCBATT_
|
— |
Start Up Operation
VCBATT_
|
— |
Vcc Under Voltage
VCBATT_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCBATT_a122.