Skip to content

UMC_a001 — Gnd Mon Intrpt Line Side

Full alert identifier: UMC_a001_gndMonIntrptLineSide

Message shown in the car

Unable to charge with Mobile Connector Inadequate outlet grounding - Try a different outlet

Alert description

UMC AC input side ground impedance exceeded threshold

Potential impact

UMC will not allow charging until the protective earth connection is corrected

Set condition

UMC AC input side ground impedance is above 1 Mohm

Clear condition

UMC AC input side ground impedance has fallen below 1 Mohm for several seconds

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Ground Impedance UMC_a001_groundImpedance Ohm

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of UMC_a001.

Browse all UMC alert codes