SCCM_a014 — Voltage Low
Full alert identifier: SCCM_a014_voltageLow
Alert description
Steering Column Control Module (SCCM) steering stalk module input power supply detected below 7.1V for 15 seconds.
Potential impact
Alert is primarily informational and used for logging purposes.
Set condition
SCCM steering stalk module input power supply detected below 7.1V for 15 seconds.
Clear condition
The alert clears automatically.
Signals to check
Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.
| Signal | Unit |
|---|---|
Voltage
SCCM_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of SCCM_a014.